Hi, I had similar issue when adding new vNIC to my VE in a wrong way (Max number of Interfaces VE v13 ESXi 5.1. This time problem showed up when I did Re-activate of the license. What's more same issue happen two times. First time on one device in DCS cluster, then on the second. For first occurrence I just gave up looking for fix, just destroyed cluster, restored default config on problematic device and recreated cluster. But now it seems to be issue that is no just separate accident but rather some kind of trend. I did such operations dozens of time in the past and never ever experienced such problem. The only specific factor in this case is, that both devices are managed by BIG-IQ (5.2.0), and I have high suspicions that it is related. It is VE 13.0.0HF2. After license reactivation situation is like that: In GUI I have message: The configuration has not yet loaded. If this message persists, it may indicate a configuration problem. tmsh load sys config ends with: Loading configuration... /config/bigip_base.conf /config/bigip_user.conf /config/bigip.conf Syntax Error:(/config/bigip.conf at line: 4201) single quotes are not balanced Referenced line in bigip.conf 4199 security dos bot-signature "/Common/T H A T ' S G O T T A H U R T" { 4200 category "/Common/Exploit Tool" 4201 rule "headercontent:\"T H A T ' S G O T T A H U R T\"; useragentonly; nocase;" 4202 user-defined false 4203 } BTW - this exactly the same spot reported as when I posted previous problem (Max number of Interfaces VE v13 ESXi 5.1 Rather can not be real reason why config is not loading??? Any ideas what to check, change really appreciated. Piotr403Views0likes6Comments